Loading HoneyMesh...
Loading HoneyMesh...
How a claim becomes evidence
A test result belongs to the exact artifact and environment exercised. An older release, a container, or a browser simulation cannot silently qualify a newer package or a physical hosting fleet.
Record ID, product, exact release, artifact type and digest, source revision where available.
Distribution, kernel, architecture, interface, driver, XDP mode, dependency versions, and topology.
The security property being tested and acceptance criteria set before the run.
A selected source, independent legitimate control traffic, and a recovery route.
Traffic profile, commands or fixtures, sample size, timing, baseline, and independent observation tools.
Actual effect, errors, counter evidence, failed or inconclusive runs, and operator actions.
Limitations and the exact claim supported by the result; no automatic transfer to another release.
Vendor, customer, or independent reviewer identity and publication approval.
Older public summaries do not yet contain every field. Missing information is shown as unpublished rather than inferred.
The current catalog describes observations and limits. These outcome labels are a proposed standard for future reviewed test runs; they are not retroactively assigned to the existing records.
| Outcome | Meaning |
|---|---|
| Pass | All preregistered acceptance criteria were met in the stated environment. |
| Partial | Only some criteria were met; the unmet checks remain visible. |
| Fail | A required criterion was contradicted by observed behavior. |
| Inconclusive | The run could not support a decision; the reason is documented. |
| Not published | No reviewed result exists in the public catalog for that check. |
V0–V6 is a proposed Network Decode classification, not an industry certification. No current product or feature is assigned a level here. A feature may have different levels for IPv4 enforcement, tenant isolation, and performance.
V0 / Designed
Architecture or specification exists.
V1 / Component tested
One component has a bounded result.
V2 / Integrated laboratory
Multiple components were exercised together in a controlled lab.
V3 / Physical infrastructure
Representative physical hardware was tested.
V4 / Scale and endurance
Sustained and fleet-scale workloads were measured.
V5 / Independent reproduction
An external party repeated a defined result.
V6 / Customer qualified
A customer accepted behavior on its own exact environment.
A comparable benchmark needs the same hardware, kernel, NIC, traffic profile, measurement window, and run conditions for baseline and candidate. Publish throughput, latency distribution, CPU, memory, sample size, variance, raw CSV, and the exact commands used. Functional packet-drop tests are not a substitute for a performance baseline.
Use external packet generators and counters alongside HoneyMesh telemetry. The XDP project tools provide XDP utilities; host tools such as bpftool, ethtool, tcpdump, and perf can provide additional observations. Tool availability and suitability must be recorded per test.
Plan adversarial testing only on owned or explicitly authorized systems. NIST SP 800-115 offers a framework for planning, conducting, and analyzing technical security assessments. For release integrity, bind the reviewed source and artifact with a digest and signed provenance where available. SLSA guidance is a reference for future provenance work; no SLSA level is claimed here.